跳至主要内容

The safety inspection of overhead crane

The safety inspection of overhead EOT crane in order to ensure the safe operation, during the operation of the need for a number of safety routine inspection, inspection items and key points are as follows:
1.The lifting height limiter, the travel limit switch and the interlock mechanism are normal, safe and reliable.
2.The main components meet the safety requirements: opening increase less than 15% of the original size, the torsional deformation is less than 10%; the 50% plate hook bushing wear is 5% smaller than the original size, the plate hook spindle wear less than 5%, no peeling, burr, welding.
3.Hook rack and pulley without obvious defects.
4.The wear and corrosion of the surface of the steel wire rope is less than 40% of the diameter of steel wire, broken wire within a twist less than 10% of the total number, no break, no thinning, no core extrusion, no blind angle twisting, no extrusion deformation, no annealing, no burning phenomenon.
5.The clips,clamp and wedge connection at the end of the wire rope connecting and fixing is intact, no loose plate, not less than 2 clamps, not less than 3 clips.
6.The drum has no crack, the connection and the fixation are not loose, and the abrasion of the cylinder wall is less than 20% of the original wall thickness; the safety volume is not less than 2 circles, and the ratio of the diameter of the drum and the steel wire meets the requirements.
7.The balance wheel is in good condition, and the wire rope should meet the requirements.
8.Brake no crack, no loose, no serious wear, brake clearance on both sides of the same size, there is sufficient braking force, brake wear is less than 50% of the original thickness.

Through the safety inspection of the overhead crane, it has played a significant role in preventing the personal accident, reducing the equipment accident, improving the running rate of equipment and reducing the maintenance cost.

评论

此博客中的热门博文

How to deal with 3 ton electric chain hoist motor overheating

Any machine has the cycle and time of operation, is not suitable for a long time continuous operation. Long time operation will cause mechanical damage and even accidents, but in general if the 3 ton electric chain hoist surface temperature is too high, we need to check what is the reason. Firstly to check whether it is because the electric hoist weight is too large, beyond the 3 ton electric chain hoist rated weight. Overweight operation will make the motor over heating, overload for a long time will cause irreparable damage to the electric chain hoists for sale.  Electric hoist motor  is not overloaded, but still heating, should check whether the motor bearing damaged; Should also check whether the motor Work according to regulations, which is one of the reasons causing the motor heating. When the electric hoist motor is running, brake clearance is too small, not completely disengaged, causing great friction, while the frictional heating is also equivalent to the additi...

The reason of electrical wire rope hoist does not work after starting

Mainly because of the hoist does not reach to the rated operating voltage, there are generally 3 kinds of situations: 1.Find out whether the power supply system supply power to wire rope electric hoist , generally used test pencil, such as no power supply; 2.The main control circuit of the wire rope electric hoist is damaged, the line is broken or the contact is bad, can also let the hoist motor not be electrified. This situation, need to overhaul the main control circuit. When maintenance, in order to prevent missing phase to burn the motor casused by the main control circuit supply power to three-phase motor, or hoist motor suddenly operate and cause danger, must disconnect electrical wire rope hoist motor from the power supply, only supply power to the main control circuit. Then start and stop switch, check and analyze the working condition of the electric appliance and the line, repair or replace the failed electric appliance or line. When the main control circuit is confirmed...

Overhead gantry crane lifting instructions

The overhead crane in workshop should not use mechanical lifting, because the top of the rail is close to the bottom chord of roof truss, in addition, the volume and weight of the heavy duty gantry crane are large. Small and medium sized overhead travelling gantry crane used single mast upright integral hoisting, which can improve work efficiency, shorten the construction period, reduce high-altitude operations, the construction procedures are as follows. Erecting mast 1.The height of the mast The maximum height of the mast is the height from the ground to the roof, minus the operating space between the top of the mast to the roof panel and the height of the sleeper. Minimum height should meet the needs of lifting height. 2.Mast position Since the mast is to be erected at the center of gravity of the travelling gantry crane between the two main girders of the trolley, the trolley must be biased, and the mast should also deviate from the centre line of the plant. The deviatio...