Pay attention to six points in the use process of CD1 type electric hoist

1.CD1 type electric cable hoist often moves on the I-beam track, the stopper must be installed at both ends of the track, to prevent the digression. The best is to assembly reliable elastic buffer or a rubber block at both ends of the wheel axle, the equivalent height of I-steel track, and I-steel track should not put out outside, if you really need to put some with rain proof device.
2.The I-steel track should be installed with grounding wire. If the grounding wire cross-sectional area of I-steel track is too small or not ground, when people contact hook, there is a risk of electric shock accident. So, the I-steel track grounding wire must be well connected, the general specification for flat 4-5mm diameter bare copper wire or a section of not less than 25mm, and should be inspected regularly.
3.Use the limiter and rope guide. The limiter limits the lifting of electric cable hoist, can prevent the hook to rise too high or too low to crash drum, or down too fast pulling the wire rope. Rope guide sleeve is mounted in a groove on the sleeve, with the axial rotation movement, the wire rope on the sleeve in order, at the same time, through the collision between the board on the rope clamp and the stop block on the limit rod, the lifting hook in the automatic limit, to ensure the safe operation of the electric hoist. The utility model relates to a spacing device and a rope guiding device, which are indispensable safety accessories of electric hoist, can effectively prevent the top of the gourd and broken rope accident.
4.Wire rope oiling maintenance method must be correct. The correct way to refuel is, when the wire rope is working, fill the oil (must use wire rope grease or thin oil, can not use butter) into the drum or pulley at the stress on the surface, sucked in the rope naturally.
5.Insist on mobile operation mode. Some companies in order to improve the working conditions for operators, will install control box to the wall, the operator can sit in a chair to remote command, convenient at the same time, increased the probability of the accident. Therefore, the control box have to be installed on the wire rope block, the control line can not be too long, let the operator move with the hoist, so as to observe the running condition of electric cable hoist at any time, and can avoid the accident.
6.Strict implementation of regular maintenance. In accordance with safety regulations, electric hoist and other lifting equipment need regular maintenance. In addition to the regular maintenance of the electric cable hoist (including the maintenance and replacement of electrical components), but also on a regular basis for overhaul, wear parts must be repaired in time. After the overhaul, in strict accordance with the rules for debugging, qualified before use.

评论

此博客中的热门博文

How to deal with 3 ton electric chain hoist motor overheating

Any machine has the cycle and time of operation, is not suitable for a long time continuous operation. Long time operation will cause mechanical damage and even accidents, but in general if the 3 ton electric chain hoist surface temperature is too high, we need to check what is the reason. Firstly to check whether it is because the electric hoist weight is too large, beyond the 3 ton electric chain hoist rated weight. Overweight operation will make the motor over heating, overload for a long time will cause irreparable damage to the electric chain hoists for sale.  Electric hoist motor  is not overloaded, but still heating, should check whether the motor bearing damaged; Should also check whether the motor Work according to regulations, which is one of the reasons causing the motor heating. When the electric hoist motor is running, brake clearance is too small, not completely disengaged, causing great friction, while the frictional heating is also equivalent to the additi...

Cause analysis of the damage of electric hoist rope

Electric drum occurs  electric chain block hoist  rope breaking phenomenon after the replacement of the drum for a short time, although the rope guide device is vulnerable parts, but in addition, there is an unexplained collapse. Rope guide specifications: unless calibration, can generally be divided into for cast steel and for cast iron, the steel drum rope guide for the lifting height above 12 meters with smaller diameter, cast iron drum rope guide for lifting height below 12 meters with large diameter. After the replacement of the drum of the  electric wire rope hoist  is not the original component, it may lead to the uneven force of the guide rope, and may be because of the installation procedure or the components do not match.  WOKAITE  recommends you, if parts damaged, must try to contact the buyer at the time of the original components. The maintenance of explosion proof hoist should be carried out in accordance with GB3836.13, the danger zone r...

Overhead gantry crane lifting instructions

The overhead crane in workshop should not use mechanical lifting, because the top of the rail is close to the bottom chord of roof truss, in addition, the volume and weight of the heavy duty gantry crane are large. Small and medium sized overhead travelling gantry crane used single mast upright integral hoisting, which can improve work efficiency, shorten the construction period, reduce high-altitude operations, the construction procedures are as follows. Erecting mast 1.The height of the mast The maximum height of the mast is the height from the ground to the roof, minus the operating space between the top of the mast to the roof panel and the height of the sleeper. Minimum height should meet the needs of lifting height. 2.Mast position Since the mast is to be erected at the center of gravity of the travelling gantry crane between the two main girders of the trolley, the trolley must be biased, and the mast should also deviate from the centre line of the plant. The deviatio...