跳至主要内容

Pay attention to six points in the use process of CD1 type electric hoist

1.CD1 type electric cable hoist often moves on the I-beam track, the stopper must be installed at both ends of the track, to prevent the digression. The best is to assembly reliable elastic buffer or a rubber block at both ends of the wheel axle, the equivalent height of I-steel track, and I-steel track should not put out outside, if you really need to put some with rain proof device.
2.The I-steel track should be installed with grounding wire. If the grounding wire cross-sectional area of I-steel track is too small or not ground, when people contact hook, there is a risk of electric shock accident. So, the I-steel track grounding wire must be well connected, the general specification for flat 4-5mm diameter bare copper wire or a section of not less than 25mm, and should be inspected regularly.
3.Use the limiter and rope guide. The limiter limits the lifting of electric cable hoist, can prevent the hook to rise too high or too low to crash drum, or down too fast pulling the wire rope. Rope guide sleeve is mounted in a groove on the sleeve, with the axial rotation movement, the wire rope on the sleeve in order, at the same time, through the collision between the board on the rope clamp and the stop block on the limit rod, the lifting hook in the automatic limit, to ensure the safe operation of the electric hoist. The utility model relates to a spacing device and a rope guiding device, which are indispensable safety accessories of electric hoist, can effectively prevent the top of the gourd and broken rope accident.
4.Wire rope oiling maintenance method must be correct. The correct way to refuel is, when the wire rope is working, fill the oil (must use wire rope grease or thin oil, can not use butter) into the drum or pulley at the stress on the surface, sucked in the rope naturally.
5.Insist on mobile operation mode. Some companies in order to improve the working conditions for operators, will install control box to the wall, the operator can sit in a chair to remote command, convenient at the same time, increased the probability of the accident. Therefore, the control box have to be installed on the wire rope block, the control line can not be too long, let the operator move with the hoist, so as to observe the running condition of electric cable hoist at any time, and can avoid the accident.
6.Strict implementation of regular maintenance. In accordance with safety regulations, electric hoist and other lifting equipment need regular maintenance. In addition to the regular maintenance of the electric cable hoist (including the maintenance and replacement of electrical components), but also on a regular basis for overhaul, wear parts must be repaired in time. After the overhaul, in strict accordance with the rules for debugging, qualified before use.

评论

此博客中的热门博文

How to deal with 3 ton electric chain hoist motor overheating

Any machine has the cycle and time of operation, is not suitable for a long time continuous operation. Long time operation will cause mechanical damage and even accidents, but in general if the 3 ton electric chain hoist surface temperature is too high, we need to check what is the reason. Firstly to check whether it is because the electric hoist weight is too large, beyond the 3 ton electric chain hoist rated weight. Overweight operation will make the motor over heating, overload for a long time will cause irreparable damage to the electric chain hoists for sale.  Electric hoist motor  is not overloaded, but still heating, should check whether the motor bearing damaged; Should also check whether the motor Work according to regulations, which is one of the reasons causing the motor heating. When the electric hoist motor is running, brake clearance is too small, not completely disengaged, causing great friction, while the frictional heating is also equivalent to the additi...

The reason of electrical wire rope hoist does not work after starting

Mainly because of the hoist does not reach to the rated operating voltage, there are generally 3 kinds of situations: 1.Find out whether the power supply system supply power to wire rope electric hoist , generally used test pencil, such as no power supply; 2.The main control circuit of the wire rope electric hoist is damaged, the line is broken or the contact is bad, can also let the hoist motor not be electrified. This situation, need to overhaul the main control circuit. When maintenance, in order to prevent missing phase to burn the motor casused by the main control circuit supply power to three-phase motor, or hoist motor suddenly operate and cause danger, must disconnect electrical wire rope hoist motor from the power supply, only supply power to the main control circuit. Then start and stop switch, check and analyze the working condition of the electric appliance and the line, repair or replace the failed electric appliance or line. When the main control circuit is confirmed...

Working level of overhead gantry crane

Overhead gantry crane  installation site and the work conditions is vary greatly, the use of lifting capacity and working frequency are also different. In order to use the crane economically and reasonably, it is necessary to choose the appropriate working level according to the working condition of the crane. The working level of the bridge crane is divided into A1 ~ A8, according to the level of the crane and the load state, that is, according to the frequency and load degree of the crane through the calculation to determine. The crane has a certain number of working cycles during its useful life. A working cycle of a  travelling gantry crane  is to start the process of loading the goods from the beginning to the next. The total number of working cycles represent the utilization of cranes. In order to facilitate the calculation, the total number of working cycles can be divided into 10 categories. 200-400 ton heavy duty travelling  overhead gantry crane for ...