Processing method for electric wire rope hoist does not work after starting

Mainly because the electrical wire rope hoist is not connected to rated working voltage and can not work, generally have the following situations
1.The power supply system output to electric wire rope hoist control box or not, generally used test pencil to test.
2.The main control loop of the electric rope hoist control box is damaged, line disconnection or poor contact, or the line of the control button is bad, will also make the hoist motor no electricity. When this kind of circumstance appeared, need to maintenance the main control circuit and the control button. Maintenance, in order to prevent burning motor caused by main power supply and control circuit for three-phase motor lack of phase, electric hoist motor or hoist damaged by suddenly running, must disconnect hoist motor from the power supply circuit, only output to the main control circuit. After the control button on the line, press the start and stop switch, check the work condition of the electrical and wiring analysis, repair or replace the faulty electric appliance or line, can be re run when confirming the main control circuit is fine.
3.Hoist motor terminal voltage low than the rated voltage of more than 10%, motor starting torque is too small, so that hoist can not lift the goods, and can not work. Check with Multimeter or voltmeter to measure the motor input voltage, determine because the voltage is too low, so that the motor can not start, the normal use of electric hoist should after the system voltage is restored. In addition, when the cross section of the external power supply line is too small, the motor can not get enough starting current and can not start.
4.Sometimes the hoist motor voltage is normal, while the hoist is not working, it should be considered for other reasons, such as motor burned, need to replace the motor; have not used hoist for a long time, poor maintenance and other reasons make the brake wheel and the end cover rust, when starting off the brake wheel, the motor only abnormal noises and can not start the gourd, unable to work. At this point, the brake wheel should be removed, clean the rust surface, and then re test. Motor sweep seriously, also make the motor does not rotate, found that this situation, should stop using, must overhaul or replace motor, in order to ensure the hoist normal work.
5.Never overload, when the goods are excessive overloading, hoist can not afford the goods, the lifting motor only abnormal noises and does not run, which will destroy the motor, even cause accidents, then immediately shut down, reduce the goods, make sure that hoist working at rated load. In order to prevent overloading, should be installed the weight overload limiter, when the lifting load reached 95% rated load automatic alarm, to automatically cut off the power supply at 105%, to achieve the purpose of overload protection.

评论

发表评论

此博客中的热门博文

How to deal with 3 ton electric chain hoist motor overheating

Any machine has the cycle and time of operation, is not suitable for a long time continuous operation. Long time operation will cause mechanical damage and even accidents, but in general if the 3 ton electric chain hoist surface temperature is too high, we need to check what is the reason. Firstly to check whether it is because the electric hoist weight is too large, beyond the 3 ton electric chain hoist rated weight. Overweight operation will make the motor over heating, overload for a long time will cause irreparable damage to the electric chain hoists for sale.  Electric hoist motor  is not overloaded, but still heating, should check whether the motor bearing damaged; Should also check whether the motor Work according to regulations, which is one of the reasons causing the motor heating. When the electric hoist motor is running, brake clearance is too small, not completely disengaged, causing great friction, while the frictional heating is also equivalent to the additi...

The reason of electrical wire rope hoist does not work after starting

Mainly because of the hoist does not reach to the rated operating voltage, there are generally 3 kinds of situations: 1.Find out whether the power supply system supply power to wire rope electric hoist , generally used test pencil, such as no power supply; 2.The main control circuit of the wire rope electric hoist is damaged, the line is broken or the contact is bad, can also let the hoist motor not be electrified. This situation, need to overhaul the main control circuit. When maintenance, in order to prevent missing phase to burn the motor casused by the main control circuit supply power to three-phase motor, or hoist motor suddenly operate and cause danger, must disconnect electrical wire rope hoist motor from the power supply, only supply power to the main control circuit. Then start and stop switch, check and analyze the working condition of the electric appliance and the line, repair or replace the failed electric appliance or line. When the main control circuit is confirmed...

Working level of overhead gantry crane

Overhead gantry crane  installation site and the work conditions is vary greatly, the use of lifting capacity and working frequency are also different. In order to use the crane economically and reasonably, it is necessary to choose the appropriate working level according to the working condition of the crane. The working level of the bridge crane is divided into A1 ~ A8, according to the level of the crane and the load state, that is, according to the frequency and load degree of the crane through the calculation to determine. The crane has a certain number of working cycles during its useful life. A working cycle of a  travelling gantry crane  is to start the process of loading the goods from the beginning to the next. The total number of working cycles represent the utilization of cranes. In order to facilitate the calculation, the total number of working cycles can be divided into 10 categories. 200-400 ton heavy duty travelling  overhead gantry crane for ...